Skip to main content

Boston-Power Swing 5300 Li-ion battery's discharge capacity test

Boston-Power is a US based manufacturer of Li-ion cells which makes them in China and Taiwan and supplies to NASA, HP, ASUS, Delfast eBike and EV makers.

The cell was bought from Queen Battery, a Chinese supplier of genuine batteries, who specializes mainly on EV and eBike market.
Boston-Power Swing 5300 Li-ion battery's discharge capacity test

The Boston-Power Swing 5300 is a 3.65V Li-ion cell with a wide working temperature range (-40 to +70°C) and impressive cycle life (1000-3000 cycles).
Boston-Power Swing 5300 Li-ion battery's discharge capacity test
Boston-Power Swing 5300 Li-ion battery's discharge capacity test

Specifications of Boston-Power Swing 5300 taken out of it's datasheet:

Nominal capacity: 5300mAh (at 0.2C discharge)
Nominal energy: 19.3Wh (at 0.2C discharge)
Nominal cell impedance: 16 mΩ
Life cycle at 100% DOD: >1000 cycles (at 1C discharge)
Discharge cut-off voltage: 2.75V
Max continuous discharge rate: 13A
Standard charging current: 3.7A, cut-off at 0.05A
Max continuous charge rate: 10.6A
Weight: 93g
Charging temperature: -20 to +60°C
Discharging temperature: -40 to +70°C
Dimensions: 37.2 x 64.8 x 19.1mm

I've tested with ZKETECH EBC-A20 and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A.


I've tried to follow all the prescriptions of the IEC61960-2003 standard concerning battery's capacity measurement. Before each discharging cycle the battery was charged at 3.7A to 4.2V (cut-off at 0.1A, which is higher than 0.05A allowed by the manufacturer, but it's the lowest supported by EBC-A20). Before each discharging or charging i've held a 1-1.5hrs pause. The environment temperature was 21-23°C.

Discharge cut-off voltage was 2.75V in all cases. I've done a 0.2C (1.06A) discharging to check the nominal capacity, then I've discharged at 5.0 and 10.0A and finished with the max allowed continuous discharge current - 13A.

The results i've grouped together, so it must be easier to compare them.

Boston-Power Swing 5300 Li-ion battery's discharge capacity test
As turned out, the battery is not overrated and at 0.2C it gives out 5318mAh - a lil bit more than the nominal capacity. The amount of energy is also slightly higher than the nominal - 19.36 vs 19.3Wh.

At 5.0A the capacity is lower than at 10.0A, but the amount of energy is higher. This is a normal thing, and the important one is the amount of energy.

At 13.0A the measured capacity was 5091mAh and the energy - 16.48Wh.

The results are good and not surprising for me. This is a high quality cell which can give out almost 5100mAh/16.5Wh at 13.0A. In some cases the prismatic form is preferable than cylindrical and i think it will help to build battery packs with higher energy density than in case of using 26650 cells with ~5000mAh capacity.

P.S. For those who think this is a double 18650 i took the heat shrink tube off to show the bare cell:
Boston-Power Swing 5300 Li-ion battery's discharge capacity test
Boston-Power Swing 5300 Li-ion battery's discharge capacity test
Boston-Power Swing 5300 Li-ion battery's discharge capacity test
Boston-Power Swing 5300 Li-ion battery's discharge capacity test
Check out my YouTube channel for batteries, chargers and other stuff reviews.

Popular posts

Sony VTC6 - a 3000mAh/30A monster in 18650 size

Sony US18650VTC6 (or just VTC6) is a high drain 18650 size Li-ion cell which supports discharge rate up to 15A if no temperature control is used and up to 30A with 80°C temperature cut. The battery was bought from my reliable supplier ( Queen Battery ) and tested  with  ZKETECH EBC-A20  and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. I've used version 3.0 of my battery holder based on 0.5mm thick pure copper terminals I've  all the prescriptions of the  IEC61960-2003  standard concerning battery's capacity measurement. Before each discharging cycle each battery was charged at standard charge current mentioned in its datasheet to charge end voltage. Before each discharging or charging i've held a 1-1.5hrs pause. The environment temperature was 23.0-24.5°C. To be sure in results i've done each test  minimum twice  (usually 3-4 times). Sony US18650VTC6 The  c ell is  marked a

Samsung 50E capacity test - 5000mAh or not?

Samsung INR21700-50E is a 21700 size cell which is being sold as 5000mAh one while in its official datasheet the capacity is mentioned as "Min. 4900mAh". I've tested it to find out it's real capacity. The battery was bought from my reliable supplier ( Queen Battery ) and tested  with  ZKETECH EBC-A20  and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. I've used version 3.0 of my battery holder based on 0.5mm thick pure copper terminals I've followed all the prescriptions of the  IEC61960-2003  standard concerning battery's capacity measurement. Before each discharging cycle each battery was charged at standard charge current mentioned in its datasheet to charge end voltage. Before each discharging or charging i've held a 1-1.5hrs pause. The environment temperature was 23.0-24.5°C. To be sure in results i've done each test minimum twice (usually 3-4 times). S

Samsung 21700 battery battle: 50G vs 48G vs 50E

Samsung has a good lineup of 21700 Li-ion batteries and when i tested INR21700-50G i thought it would be interesting to test INR21700-48G cell too because the new batch of 48Gs came in green heat shrink tube (the version i tested before was gray). Then i added 50E results to comparison as they are very close in capacity and max discharge rate. The batteries were bought from Queen Battery which is my reliable supplier of genuine cells and tested with ZKETECH EBC-A20 and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. 50G and 48G cells were tested using my battery holder v.4.0. A detailed video about it is available on my channel. I've followed all the prescriptions of the IEC61960-2003 standard concerning battery's capacity measurement. Before each discharging cycle the battery was charged at standard charge current mentioned in its datasheet to charge end voltage. Before each discharging or char

3500mAh 18650 Li-ion cells' discharge capacity test (Sanyo NCR18650GA vs Panasonic NCR18650GA vs LG MJ1 vs Samsung INR18650-35E)

Hi guys! I’ve got four 3500mAh batteries from top manufacturers. I’ve tested and compared them. I think it’s interesting not only for me, but also for you, the guy who is reading this:) The cells were bought from Queen Battery , a Chinese supplier of genuine batteries, who specializes mainly on EV and eBike market. Queen Battery has a branch in Europe, but they also work with customers from Americas, Russia, etc… As always, I've tested with ZKETECH EBC-A20 and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. I've followed all the prescriptions of the IEC61960-2003 standard concerning battery's capacity measurement. Before each discharging cycle each battery was charged at standard current mentioned in its datasheet to 4.2V (cut-off at 0.1A, which is the lowest supported by EBC-A20). Before each discharging or charging i've held a 1-1.5hrs pause. The environment temperature was 20-

Samsung 40T - high drain 21700 Li-ion battery's capacity test

Hi guys! I've tested the Samsung INR21700-40T (35A) at up to 20A discharge (limited by my equipment). The battery was bought from my reliable supplier ( Queen Battery ) and tested  with  ZKETECH EBC-A20  and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. I've used version 3.0 of my battery holder based on 0.5mm thick pure copper terminals I've followed all the prescriptions of the  IEC61960-2003  standard concerning battery's capacity measurement. Before each discharging cycle each battery was charged at standard charge current mentioned in its datasheet to charge end voltage. Before each discharging or charging i've held a 1-1.5hrs pause. The environment temperature was 23.5-24.5°C. To be sure in results i've done each test minimum twice (usually 3-4 times). Samsung INR21700-40T The c ell is marked as  INR21700-40T SAMSUNG SDI 2I15 which mean s that the production d

Li-ion 21700: LG M50 5000mAh vs Samsung 48G 4800mAh discharge capacity test

Hi guys! I've tested two high capacity 21700 cells - LG M50 (5000mAh) and Samsung 48G (4800mAh). The latter i had already tested before and the re-testing of another cell showed almost no difference with previous test results. The M50 is a new cell which is being sold as 10A one, but in its datasheet the maximum discharge current is mentioned as 7.28A. Nevertheless i've also discharged it at 10A to look at it's behavior. The cells i've bought from Queen Battery . As always, I've tested with ZKETECH EBC-A20 and a self-made battery holder. It's a PC-connected battery tester supporting 4-wire measuring and discharging at up to 20A. I've used the v2.5 of my battery holder I've followed all the prescriptions of the IEC61960-2003 standard concerning battery's capacity measurement. Before each discharging cycle each battery was charged at standard current mentioned in its datasheet to charge end voltage (4.2V) (cut-off at 0.1A, which is th